コンテンツにスキップ
プロのオーディオ、照明、AV ケーブルの製造
LBS LBS AudioCable Factory乐宝声(广东)线缆科技有限公司
🇯🇵 日本語
LBSUTP-C6A

Cat6A UTP シールドなしツイストペア ケーブル

23 AWG ソリッド 4N OFC 導体、内部クロスフィラー スプライン、250 MHz 帯域幅を備えたシールドなし Cat6A ケーブル。

速度/帯域幅1000 Mbps / 250 MHz
ジャケットの色Blue
ジャケット外径6.2 / 6.4 / 7.2 mm
ジャケットEPVC
主導体23 AWG / 0.25
温度-20°C to 70°C

Cat6A UTP Unshielded Twisted Pair Cable. 23AWG solid 4N OFC conductors, cross-filler spline, blue PVC jacket, operating range -20 to +70C. 1Gbps/250MHz. From LBS Catalog 2026.

Cat6A UTP for Gigabit and AV-over-IP Horizontal Runs

This Cat6A UTP cable is the unshielded option in the LBS Cat6A family. It delivers the same 23AWG solid 4N OFC conductor and cross-filler spline construction as the shielded Cat6A versions, with a simpler jacket that is easier to terminate in patch panels and wall outlets. Cat6A UTP is a practical choice for horizontal cabling inside buildings where data and AV-over-IP runs are separated from power and lighting circuits, and where an unshielded construction is easier to terminate at patch panels and outlets than a shielded one.

For runs close to dimmer packs, motors or high-voltage feeders, choose the shielded options instead — compare the Cat6A FTP (foil shield) or Cat6A SFTP (foil plus braid). See UTP vs FTP vs SFTP Ethernet Cable for the full shielding comparison.

Applications / 应用

Horizontal Gigabit data cabling, AV-over-IP (Dante, AVB, NDI), IP cameras, access control and general network installation where shielding is not required.

Gigabit 水平数据布线、AV-over-IP(Dante、AVB、NDI)、IP 摄像头、门禁及常规网络工程(无屏蔽需求场景)。

Cat6A UTP FAQ

Q: When should I choose Cat6A UTP instead of FTP or SFTP?
A: Choose UTP for indoor horizontal runs where the data cable is kept away from power and lighting interference. Choose FTP or SFTP when the cable runs beside power feeders, dimmers or motors.

Q: Does Cat6A UTP support 10Gbps?
A: The LBS 2026 catalog lists this unshielded Cat6A construction as Gigabit Ethernet (1000 Mbps / 1 Gbps) with transmission bandwidth up to 250 MHz. The shielding choice affects noise immunity, not the Gigabit rating. Where a 10 Gbps / 500 MHz backbone is specified, LBS supplies the Cat6A S/FTP 10G construction (LBS6ASSTP-C6A).

Q: Can LBS supply Cat6A UTP with custom printing?
A: Custom jacket printing, colour, length and packaging can be reviewed as part of an OEM / ODM project — send the requirement through the contact page or WhatsApp.

Cat6A Family Comparison: UTP / FTP / SFTP / S-FTP 10G

Every Cat6A construction in the LBS range shares the same 23 AWG solid 4N OFC conductor and an internal cross-filler spline that keeps the four pairs separated. The buyer choice is the shielding level — and, for the 10G backbone item, the insulation and bandwidth rating. The table uses the values published in the LBS 2026 product catalog, Cat6A series:

Item / construction Shielding Jacket O.D. Main conductor Catalogued speed / bandwidth
Cat6A UTP (LBSUTP-C6A) (this page)
Unshielded twisted pair
None 6.2 / 6.4 / 7.2 mm 23 AWG / 0.25 Gigabit Ethernet (1000 Mbps / 1 Gbps), up to 250 MHz
Cat6A FTP (LBSFTP-C6A)
Foil shield + tinned-copper drain wire
AL-foil + drain wire 7.2 mm 23 AWG / 0.25 Gigabit Ethernet (1000 Mbps / 1 Gbps), up to 250 MHz
Cat6A SFTP (LBSSFTP-C6A)
AL-foil plus overall tinned-copper braid
Foil + braid (double) 7.8 mm 23 AWG / 0.26 Gigabit Ethernet (1000 Mbps / 1 Gbps), up to 250 MHz
Cat6A S/FTP 10G (LBS6ASSTP-C6A)
Individually foil-shielded pairs + overall tinned-copper braid, Foam-PE insulation
Foil per pair + braid 8 mm 23 AWG / 0.26 10 Gigabit (10 Gbps), up to 500 MHz

All four constructions: blue PVC jacket, applicable temperature -20°C to +70°C. Source: LBS 2026 product catalog, Cat6A series. Confirm the exact SKU and construction for your project before ordering.

Selection rule: pick the lowest shielding level the installation actually needs — UTP for clean dedicated data/AV runs, FTP where the run passes near power feeders or lighting circuits, SFTP on stage floors, touring racks and high-EMI routes, and the Cat6A S/FTP 10G item where a 10 Gbps / 500 MHz backbone is specified. For the shielding comparison in detail, see the UTP vs FTP vs SFTP Ethernet Cable guide.

Cat6A 系列对比:四种结构同为 23 AWG 实心 4N 无氧铜导体并带十字骨架,区别在屏蔽等级;表中数值取自 LBS 2026 产品目录 Cat6A 系列页。

📥 Download Full Product Catalog (PDF)

Conduit and tray fit: what the published O.D. decides

The published Jacket O.D. of this model is 6.2 / 6.4 / 7.2 mm, so a tight conduit has to be sized on the largest of the three values and confirmed against the specification table quoted with the order. At a 40 % fill, a conduit with a 25 mm internal diameter takes six cables at 6.2–6.4 mm and four at 7.2 mm. Moving one step up the shielding scale costs conduit capacity, because the same family is published at 7.2 mm for FTP, 7.8 mm for SFTP and 8.0 mm for the S-FTP 10G model.

The fill percentages, the area arithmetic and a count table covering every published LBS speaker, DMX512, microphone and network outside diameter are in cable outside diameter and conduit fill.

Related Guides

製品調達に関するよくある質問

お見積りを依頼する前に

これらの回答には、このページに表示されている製品情報が使用されています。最終的なプロジェクト条件は確認された仕様によって異なります。

LBSUTP-C6A を見積もるにはどのような情報が必要ですか

ご希望の仕様、長さまたは梱包単位、数量、用途、送り先の国または地域をお知らせください。

Cat6A UTP シールドなしツイストペア ケーブル を OEM / ODM プロジェクトで議論できますか?

確認された製品とプロジェクトの数量に応じて、構造、ジャケットの色、印刷、長さ、パッケージング、およびブランディングを検討できます。

正しいバリアントを選択するにはどうすればよいですか?

このページの技術仕様表を比較し、バリアントの確認にサポートが必要な場合は、アプリケーションと必要な寸法を LBS に送信してください。

見積もりを依頼する

この商品について質問する

以下の主要な詳細を入力してください。メッセージは LBS 営業に直接送信され、WordPress に潜在顧客レコードとして意図的に保存されることはありません。

代わりに WhatsApp を使用してください

OEM/ODMのお問い合わせ

あなたのプロジェクトに何が必要かを教えてください。

型式、仕様、数量、送付先をお送りください。私たちのチームが次のステップについて返信します。

WhatsApp 見積もりを取得する