Cat6A UTP 비차폐 연선 케이블
23AWG 솔리드 4N OFC 도체, 내부 크로스 필러 스플라인 및 250MHz 대역폭을 갖춘 비차폐 Cat6A 케이블입니다.
| 속도 / 대역폭 | 1000 Mbps / 250 MHz |
|---|---|
| 재킷 색상 | Blue |
| 재킷 O.D. | 6.2 / 6.4 / 7.2 mm |
| 재킷 | EPVC |
| 주요 지휘자 | 23 AWG / 0.25 |
| 온도 | -20°C to 70°C |


23AWG 솔리드 4N OFC 도체, 내부 크로스 필러 스플라인 및 250MHz 대역폭을 갖춘 비차폐 Cat6A 케이블입니다.
| 속도 / 대역폭 | 1000 Mbps / 250 MHz |
|---|---|
| 재킷 색상 | Blue |
| 재킷 O.D. | 6.2 / 6.4 / 7.2 mm |
| 재킷 | EPVC |
| 주요 지휘자 | 23 AWG / 0.25 |
| 온도 | -20°C to 70°C |
Cat6A UTP Unshielded Twisted Pair Cable. 23AWG solid 4N OFC conductors, cross-filler spline, blue PVC jacket, operating range -20 to +70C. 1Gbps/250MHz. From LBS Catalog 2026.
This Cat6A UTP cable is the unshielded option in the LBS Cat6A family. It delivers the same 23AWG solid 4N OFC conductor and cross-filler spline construction as the shielded Cat6A versions, with a simpler jacket that is easier to terminate in patch panels and wall outlets. Cat6A UTP is a practical choice for horizontal cabling inside buildings where data and AV-over-IP runs are separated from power and lighting circuits, and where an unshielded construction is easier to terminate at patch panels and outlets than a shielded one.
For runs close to dimmer packs, motors or high-voltage feeders, choose the shielded options instead — compare the Cat6A FTP (foil shield) or Cat6A SFTP (foil plus braid). See UTP vs FTP vs SFTP Ethernet Cable for the full shielding comparison.
Horizontal Gigabit data cabling, AV-over-IP (Dante, AVB, NDI), IP cameras, access control and general network installation where shielding is not required.
Gigabit 水平数据布线、AV-over-IP(Dante、AVB、NDI)、IP 摄像头、门禁及常规网络工程(无屏蔽需求场景)。
Q: When should I choose Cat6A UTP instead of FTP or SFTP?
A: Choose UTP for indoor horizontal runs where the data cable is kept away from power and lighting interference. Choose FTP or SFTP when the cable runs beside power feeders, dimmers or motors.
Q: Does Cat6A UTP support 10Gbps?
A: The LBS 2026 catalog lists this unshielded Cat6A construction as Gigabit Ethernet (1000 Mbps / 1 Gbps) with transmission bandwidth up to 250 MHz. The shielding choice affects noise immunity, not the Gigabit rating. Where a 10 Gbps / 500 MHz backbone is specified, LBS supplies the Cat6A S/FTP 10G construction (LBS6ASSTP-C6A).
Q: Can LBS supply Cat6A UTP with custom printing?
A: Custom jacket printing, colour, length and packaging can be reviewed as part of an OEM / ODM project — send the requirement through the contact page or WhatsApp.
Every Cat6A construction in the LBS range shares the same 23 AWG solid 4N OFC conductor and an internal cross-filler spline that keeps the four pairs separated. The buyer choice is the shielding level — and, for the 10G backbone item, the insulation and bandwidth rating. The table uses the values published in the LBS 2026 product catalog, Cat6A series:
| Item / construction | Shielding | Jacket O.D. | Main conductor | Catalogued speed / bandwidth |
|---|---|---|---|---|
| Cat6A UTP (LBSUTP-C6A) (this page) Unshielded twisted pair |
None | 6.2 / 6.4 / 7.2 mm | 23 AWG / 0.25 | Gigabit Ethernet (1000 Mbps / 1 Gbps), up to 250 MHz |
| Cat6A FTP (LBSFTP-C6A) Foil shield + tinned-copper drain wire |
AL-foil + drain wire | 7.2 mm | 23 AWG / 0.25 | Gigabit Ethernet (1000 Mbps / 1 Gbps), up to 250 MHz |
| Cat6A SFTP (LBSSFTP-C6A) AL-foil plus overall tinned-copper braid |
Foil + braid (double) | 7.8 mm | 23 AWG / 0.26 | Gigabit Ethernet (1000 Mbps / 1 Gbps), up to 250 MHz |
| Cat6A S/FTP 10G (LBS6ASSTP-C6A) Individually foil-shielded pairs + overall tinned-copper braid, Foam-PE insulation |
Foil per pair + braid | 8 mm | 23 AWG / 0.26 | 10 Gigabit (10 Gbps), up to 500 MHz |
All four constructions: blue PVC jacket, applicable temperature -20°C to +70°C. Source: LBS 2026 product catalog, Cat6A series. Confirm the exact SKU and construction for your project before ordering.
Selection rule: pick the lowest shielding level the installation actually needs — UTP for clean dedicated data/AV runs, FTP where the run passes near power feeders or lighting circuits, SFTP on stage floors, touring racks and high-EMI routes, and the Cat6A S/FTP 10G item where a 10 Gbps / 500 MHz backbone is specified. For the shielding comparison in detail, see the UTP vs FTP vs SFTP Ethernet Cable guide.
Cat6A 系列对比:四种结构同为 23 AWG 实心 4N 无氧铜导体并带十字骨架,区别在屏蔽等级;表中数值取自 LBS 2026 产品目录 Cat6A 系列页。
📥 Download Full Product Catalog (PDF)
The published Jacket O.D. of this model is 6.2 / 6.4 / 7.2 mm, so a tight conduit has to be sized on the largest of the three values and confirmed against the specification table quoted with the order. At a 40 % fill, a conduit with a 25 mm internal diameter takes six cables at 6.2–6.4 mm and four at 7.2 mm. Moving one step up the shielding scale costs conduit capacity, because the same family is published at 7.2 mm for FTP, 7.8 mm for SFTP and 8.0 mm for the S-FTP 10G model.
The fill percentages, the area arithmetic and a count table covering every published LBS speaker, DMX512, microphone and network outside diameter are in cable outside diameter and conduit fill.
제품 소싱 FAQ
이러한 답변은 이 페이지에 표시된 제품 정보를 사용합니다. 최종 프로젝트 기간은 확정된 사양에 따라 달라집니다.
필요한 사양, 길이 또는 포장 단위, 수량, 용도 및 도착 국가 또는 지역을 알려주십시오.
확정된 제품 및 프로젝트 수량에 따라 구성, 재킷 색상, 프린팅, 길이, 포장, 브랜딩 등을 검토할 수 있습니다.
이 페이지의 기술 사양 표를 비교한 후 변형 확인에 도움이 필요한 경우 LBS에 애플리케이션과 필수 치수를 보내주세요.
견적을 요청하세요
아래의 주요 세부정보를 작성하세요. 메시지는 LBS 영업팀으로 직접 전송되며 의도적으로 WordPress의 리드 레코드로 저장되지 않습니다.