Перейти к содержимому
Производство профессионального аудио, освещения и AV-кабелей
LBS LBS AudioCable Factory乐宝声(广东)线缆科技有限公司
🇷🇺 Русский
LBSDMX128035-1

Одноэкранированный кабель управления освещением DMX512

Одноэкранированный 2-жильный экранированный кабель управления освещением DMX512 для сценического освещения, оплетка 128/2×0,35, оболочка из матового EPVC 6,3 мм, спиральный экран из OFC высокой плотности (покрытие 85%).

Пункт №.LBSDMX128035
Дирижеры2
Цвет курткиBlack / brown / dark green optional
Куртка О.Д.6.3 mm
КурткаEPVC MATT
ЭкранированиеSingle shield — high-density OFC spiral, 85%+ coverage
плетение128 / 2 × 0.35
Применимая температура-20°C to 70°C

Features

Elastic PVC jacket, PE insulation, high-density OFC spiral shielding (85%+ coverage) for reliable DMX512 signal transmission.

Applications / 应用

DMX512 lighting control, stage equipment, KTV and professional show installations.

DMX512灯光控制、舞台设备、KTV与专业演出应用。

OEM and Customisation for DMX512 Lighting Control Cable

The LBSDMX series can be produced to your specification for branded or project requirements:

  • Conductor and construction: 2-core DMX512 lighting control cable with PE insulation, high-density OFC spiral shielding (85%+ coverage) for reliable DMX512 signal transmission
  • Jacket: Elastic PVC, available in black or custom colours
  • Printing: Your brand name, model number and specification printed on the jacket
  • Packaging: 100m rolls, 305m drums or custom lengths for distributor stocking
  • Pre-assembly: XLR male/female termination available on request

Contact us for OEM DMX512 lighting control cable quotation →

Applications

  • Stage and live sound: DMX512 lighting control lines for stage fixtures and LED
  • Broadcast and studio: Balanced audio routing with low-noise shielding
  • KTV and commercial AV: Durable DMX512 lighting control cabling for installed systems
  • AV equipment: Channel audio connections in racks and patch panels

LBSDMX DMX512 Lighting Control Cable Series — Variants

Compare the LBSDMX DMX512 lighting control cable models to match the conductor size to your run length:

Model Braiding (cores × conductor) Typical use Product page
LBSDMX64025 64 / 2 × 0.25 Short DMX fixture drops, patch View
LBSDMX96035 96 / 2 × 0.35 Standard DMX runs View
LBSDMX128035 128 / 2 × 0.35 Longer DMX runs, daisy chains Current page
LBSDMX144050 144 / 2 × 0.50 Heavy-duty touring, long runs View

Multichannel stage snakes from 4 to 48 channels are also available in the LBSDMX multichannel series.

FAQ

What is the minimum order quantity for LBSDMX DMX512 lighting control cable?

Standard models are available from stock in 100m rolls. For OEM orders with custom printing and packaging, please send your project requirements for a tailored quotation.

Can the jacket colour and printing be customised for my brand?

Yes. Custom jacket colours and permanent cable printing with your brand name, model code and specification are available for OEM orders.

Can DMX512 lighting control cable be terminated with XLR connectors?

Yes, LBS offers pre-assembled XLR terminated DMX512 lighting control cables on request. Please confirm your connector specification, length and quantity.

Is this cable suitable for balanced audio?

Yes, the LBSDMX128035 uses high-density OFC spiral shielding (85%+ coverage) and a twisted-pair construction suitable for balanced DMX512 lighting control and line-level audio signals.

Related Guides

DMX512 impedance: what the standard says, and what this data sheet states

DMX512 runs on the RS-485 electrical layer. RS-485 is specified around a 120 Ω nominal characteristic impedance on shielded twisted-pair cable, and impedance comes from the construction — conductor spacing, insulation and shield geometry — not from the copper size alone.

LBS publishes 120 Ω on the double-shielded LBSDMX…-2 models. On this single-shielded model the published data sheet states shield type, braiding, jacket O.D. and temperature range, and does not state an impedance figure. If your project documentation has to carry one, request the value against this model instead of assuming it.

Why the figure matters: DMX termination and daisy-chain rules →

DMX512 single shielded stage lighting control cable construction diagram

Single-shield or double-shield: what the order has to state

LBS builds two DMX512 families with the same two conductors, the same 6.3 mm matt EPVC jacket and the same -20 °C to +70 °C rating. The difference is the shield, and that is the line the purchase order has to be specific about.

Construction Shield Impedance on the published data sheet Model example
Single-shielded (this page) High-density OFC spiral, 85%+ coverage Not stated LBSDMX128035
Double-shielded 100% coverage AL-Foil plus heavy-duty tinned-copper braid 120 Ω LBSDMX128035-2

Where the run shares a tray, a truss or a cable path with dimmer racks, LED power supplies or motor drives, the foil layer under the braid is the reason to specify the double-shielded construction. Where the data pair is routed clear of that equipment, the single-shielded spiral is the simpler build and the usual choice.

See the double-shielded LBSDMX128035-2 construction →  ·  All DMX lighting cable

Can DMX512 cable be replaced with Cat6?

Not for the bus. DMX512 is specified as a 120 Ω shielded twisted pair, and Cat5e / Cat6 is specified at a nominal 100 Ω ±15 Ω. Those are different physical layers, so a network pair is not a substitute for this cable on a lighting run, however good that cable is for its own purpose.

Cat5e / Cat6 is the right cable in the other case: when the DMX universes travel as Ethernet traffic between a console and a node — Art-Net or sACN (ANSI E1.31) — and the node then outputs conventional DMX512 to the fixtures. The rule for a purchase list is that the cable follows the port: a 5-pin XLR DMX output takes DMX512 cable (this page), an RJ45 output takes network cable plus a node at the far end.

DMX over Cat6: can you run DMX512 on Ethernet cable? sets out both cases, the symptoms each one produces and what the order has to state.

Confirm these three points before this model is quoted

  • Shield level — this page is the single-shielded build (high-density OFC spiral, 85%+ coverage). Where the run shares a tray, truss or cable path with dimmer racks, LED power supplies or motor drives, the double-shielded foil-plus-braid build is the construction to specify.
  • Whether a stated impedance figure is required — this single-shielded data sheet publishes construction, jacket O.D. and temperature range, not a characteristic-impedance value. If the project documentation has to carry one, say so in the enquiry.
  • Length, packing and termination — 100 m rolls, 305 m drums or custom lengths, with XLR male/female pre-assembly available on request.

ПОИСК ПРОДУКЦИИ: часто задаваемые вопросы

Прежде чем запросить предложение

В этих ответах используется информация о продукте, показанная на этой странице. Окончательные сроки проекта зависят от утвержденного технического задания.

Какая информация необходима для цитирования LBSDMX128035-1

Пожалуйста, укажите необходимую спецификацию, длину или упаковочную единицу, количество, применение и страну или регион назначения.

Может ли Одноэкранированный кабель управления освещением DMX512 обсуждаться для OEM/ODM-проекта?

Конструкция, цвет оболочки, печать, длина, упаковка и брендинг могут быть проверены в соответствии с подтвержденным количеством продукта и проекта.

Как выбрать правильный вариант?

Сравните таблицу технических характеристик на этой странице, затем отправьте LBS заявку и необходимые размеры, если вам нужна помощь в подтверждении варианта.

ЗАПРОСИТЬ ЦЕНУ

Спросить об этом продукте

Заполните ключевые данные ниже. Сообщение отправляется непосредственно в отдел продаж LBS и не сохраняется намеренно в качестве записи интереса в WordPress.

OEM / ODM-запрос

Расскажите нам, что нужно вашему проекту.

Отправьте модель, спецификацию, количество и пункт назначения. Наша команда ответит следующим шагом.

WhatsApp Получить цену