콘텐츠로 건너뛰기
전문 오디오, 조명
LBS LBS AudioCable Factory乐宝声(广东)线缆科技有限公司
🇰🇷 한국어

Cat6A FTP 차폐 연선 케이블

Cat6A FTP 차폐 연선 케이블. AL 포일 쉴드, 주석 도금 구리 드레인 와이어, 파란색 PVC 재킷, O.D. 7.2mm, 23AWG 솔리드 4N OFC, 크로스 필러 스플라인, -20~70C. 1Gbps/250MHz. LBS 카탈로그 2026에서. Cat6A FTP for Shielded 10Gbps Runs This Cat6A FTP cable adds an aluminium-foil shield and tinned-copper drain wire over the 23AWG solid 4N OFC Cat6A […]

Cat6A FTP 차폐 연선 케이블. AL 포일 쉴드, 주석 도금 구리 드레인 와이어, 파란색 PVC 재킷, O.D. 7.2mm, 23AWG 솔리드 4N OFC, 크로스 필러 스플라인, -20~70C. 1Gbps/250MHz. LBS 카탈로그 2026에서.

Cat6A FTP for Shielded 10Gbps Runs

This Cat6A FTP cable adds an aluminium-foil shield and tinned-copper drain wire over the 23AWG solid 4N OFC Cat6A core. The foil shield provides protection against external interference while the drain wire gives a clean termination point for the shield. Cat6A FTP is a practical middle option for 10Gbps horizontal runs where the cable passes near power feeders or lighting circuits but a full double-shielded SFTP cable is not required.

Compare the shielding levels in the LBS Cat6A family:Cat6A UTP(unshielded), this FTP (foil), andCat6A SFTP(foil plus braid). SeeUTP 대 FTP 대 SFTP 이더넷 케이블for the full comparison, and theLBS6ASSTP-C6A Cat6A S/FTP 10G 케이블for the double-shielded backbone option.

응용프로그램 / 应용

10Gbps data backbones, AV-over-IP (Dante, AVB, NDI), building network risers, PoE+ cameras and general commercial network installation where foil shielding is specified.

Cat6A FTP FAQ

Q: What is the difference between Cat6A FTP and Cat6A SFTP?
A: FTP uses one aluminium-foil shield over the core. SFTP uses foil plus an overall tinned-copper braid for double shielding, giving more noise immunity in electrically noisy environments.

Q: Does Cat6A FTP support 10Gbps?
A: Yes. Cat6A is specified for 10GBASE-T up to 100 metres; the shield type affects noise immunity, not the 10G capability.

Q: Can the drain wire be terminated in standard RJ45?
A: The drain wire is intended to be connected to the shield at the patch panel or equipment end. Your installer should follow the connector manufacturer’s shielded termination instructions.

📥 전체 제품 카탈로그 다운로드(PDF)

AV over IP Network Cable Selection

In an AV-over-IP project — Dante audio, NDI video, SDVoE or control networks — the Cat6A FTP construction is often the practical choice for links that run through equipment racks, cable trays and corridors where some electrical noise exists but a full double-shielded cable is not required. Three selection rules apply:

  • Shielding level follows the environment.Clean dedicated AV network runs can use Cat6A UTP; runs near dimmers, lighting racks or power feeders should use at least FTP; stage floors, touring racks and high-EMI locations should use Cat6A SFTP.
  • Category follows the protocol.Gigabit audio control systems run comfortably on Cat6A at 250 MHz; video-heavy systems (4K over NDI or SDVoE) benefit from the 10 Gbps / 500 MHz Cat6A S/FTP backbone.
  • Keep one construction per link.Mixing UTP and FTP sections on the same run creates grounding and performance questions — standardise the family on one shielding level per zone.

The LBS Cat6A family covers all three shielding levels with the same 23 AWG solid OFC core and cross-filler spline:Cat6A UTP, thisCat6A FTP,Cat6A SFTP그리고Cat6A S/FTP 10G. For a full AV-over-IP specification walkthrough, see theAV over IP network cable guide.

Related Guides

제품 소싱 FAQ

견적을 요청하기 전에

이러한 답변은 이 페이지에 표시된 제품 정보를 사용합니다. 최종 프로젝트 기간은 확정된 사양에 따라 달라집니다.

인용하려면 어떤 정보가 필요한가요?

필요한 사양, 길이 또는 포장 단위, 수량, 용도 및 도착 국가 또는 지역을 알려주십시오.

OEM/ODM 프로젝트에서 Cat6A FTP 차폐 연선 케이블을 논의할 수 있나요?

확정된 제품 및 프로젝트 수량에 따라 구성, 재킷 색상, 프린팅, 길이, 포장, 브랜딩 등을 검토할 수 있습니다.

올바른 변형을 선택하는 방법

이 페이지의 기술 사양 표를 비교한 후 변형 확인에 도움이 필요한 경우 LBS에 애플리케이션과 필수 치수를 보내주세요.

견적을 요청하세요

케이블 요구 사항 보내기

아래의 주요 세부정보를 작성하세요. 메시지는 LBS 영업팀으로 직접 전송되며 의도적으로 WordPress의 리드 레코드로 저장되지 않습니다.

OEM/ODM문의

귀하의 프로젝트에 필요한 것이 무엇인지 알려주십시오.

모델, 사양, 수량 및 목적지를 보내십시오. 저희 팀에서 다음 단계로 답변해 드리겠습니다.

WhatsApp 견적 받기