LBSDMX128035-1

단일 차폐 DMX512 조명 제어 케이블

무대 조명용 단일 차폐 2코어 차폐 DMX512 조명 제어 케이블, 편조 128/2 × 0.35, 6.3mm 무광택 EPVC 재킷, 고밀도 OFC 나선형 차폐(85% 적용 범위).

품목 번호LBSDMX128035
지휘자2
재킷 색상Black / brown / dark green optional
재킷 O.D.6.3 mm
재킷EPVC MATT
차폐Single shield — high-density OFC spiral, 85%+ coverage
땋기128 / 2 × 0.35
적용온도-20°C to 70°C

Features

Elastic PVC jacket, PE insulation, high-density OFC spiral shielding (85%+ coverage) for reliable DMX512 signal transmission.

Applications / 应用

DMX512 lighting control, stage equipment, KTV and professional show installations.

DMX512灯光控制、舞台设备、KTV与专业演出应用。

OEM and Customisation for DMX512 Lighting Control Cable

The LBSDMX series can be produced to your specification for branded or project requirements:

  • Conductor and construction: 2-core DMX512 lighting control cable with PE insulation, high-density OFC spiral shielding (85%+ coverage) for reliable DMX512 signal transmission
  • Jacket: Elastic PVC, available in black or custom colours
  • Printing: Your brand name, model number and specification printed on the jacket
  • Packaging: 100m rolls, 305m drums or custom lengths for distributor stocking
  • Pre-assembly: XLR male/female termination available on request

Contact us for OEM DMX512 lighting control cable quotation →

Applications

  • Stage and live sound: DMX512 lighting control lines for stage fixtures and LED
  • Broadcast and studio: Balanced audio routing with low-noise shielding
  • KTV and commercial AV: Durable DMX512 lighting control cabling for installed systems
  • AV equipment: Channel audio connections in racks and patch panels

LBSDMX DMX512 Lighting Control Cable Series — Variants

Compare the LBSDMX DMX512 lighting control cable models to match the conductor size to your run length:

Model Braiding (cores × conductor) Typical use Product page
LBSDMX64025 64 / 2 × 0.25 Short DMX fixture drops, patch View
LBSDMX96035 96 / 2 × 0.35 Standard DMX runs View
LBSDMX128035 128 / 2 × 0.35 Longer DMX runs, daisy chains Current page
LBSDMX144050 144 / 2 × 0.50 Heavy-duty touring, long runs View

Multichannel stage snakes from 4 to 48 channels are also available in the LBSDMX multichannel series.

FAQ

What is the minimum order quantity for LBSDMX DMX512 lighting control cable?

Standard models are available from stock in 100m rolls. For OEM orders with custom printing and packaging, please send your project requirements for a tailored quotation.

Can the jacket colour and printing be customised for my brand?

Yes. Custom jacket colours and permanent cable printing with your brand name, model code and specification are available for OEM orders.

Can DMX512 lighting control cable be terminated with XLR connectors?

Yes, LBS offers pre-assembled XLR terminated DMX512 lighting control cables on request. Please confirm your connector specification, length and quantity.

Is this cable suitable for balanced audio?

Yes, the LBSDMX128035 uses high-density OFC spiral shielding (85%+ coverage) and a twisted-pair construction suitable for balanced DMX512 lighting control and line-level audio signals.

Related Guides

DMX512 impedance: what the standard says, and what this data sheet states

DMX512 runs on the RS-485 electrical layer. RS-485 is specified around a 120 Ω nominal characteristic impedance on shielded twisted-pair cable, and impedance comes from the construction — conductor spacing, insulation and shield geometry — not from the copper size alone.

LBS publishes 120 Ω on the double-shielded LBSDMX…-2 models. On this single-shielded model the published data sheet states shield type, braiding, jacket O.D. and temperature range, and does not state an impedance figure. If your project documentation has to carry one, request the value against this model instead of assuming it.

Why the figure matters: DMX termination and daisy-chain rules →

DMX512 single shielded stage lighting control cable construction diagram

Single-shield or double-shield: what the order has to state

LBS builds two DMX512 families with the same two conductors, the same 6.3 mm matt EPVC jacket and the same -20 °C to +70 °C rating. The difference is the shield, and that is the line the purchase order has to be specific about.

Construction Shield Impedance on the published data sheet Model example
Single-shielded (this page) High-density OFC spiral, 85%+ coverage Not stated LBSDMX128035
Double-shielded 100% coverage AL-Foil plus heavy-duty tinned-copper braid 120 Ω LBSDMX128035-2

Where the run shares a tray, a truss or a cable path with dimmer racks, LED power supplies or motor drives, the foil layer under the braid is the reason to specify the double-shielded construction. Where the data pair is routed clear of that equipment, the single-shielded spiral is the simpler build and the usual choice.

See the double-shielded LBSDMX128035-2 construction →  ·  All DMX lighting cable

Can DMX512 cable be replaced with Cat6?

Not for the bus. DMX512 is specified as a 120 Ω shielded twisted pair, and Cat5e / Cat6 is specified at a nominal 100 Ω ±15 Ω. Those are different physical layers, so a network pair is not a substitute for this cable on a lighting run, however good that cable is for its own purpose.

Cat5e / Cat6 is the right cable in the other case: when the DMX universes travel as Ethernet traffic between a console and a node — Art-Net or sACN (ANSI E1.31) — and the node then outputs conventional DMX512 to the fixtures. The rule for a purchase list is that the cable follows the port: a 5-pin XLR DMX output takes DMX512 cable (this page), an RJ45 output takes network cable plus a node at the far end.

DMX over Cat6: can you run DMX512 on Ethernet cable? sets out both cases, the symptoms each one produces and what the order has to state.

Confirm these three points before this model is quoted

  • Shield level — this page is the single-shielded build (high-density OFC spiral, 85%+ coverage). Where the run shares a tray, truss or cable path with dimmer racks, LED power supplies or motor drives, the double-shielded foil-plus-braid build is the construction to specify.
  • Whether a stated impedance figure is required — this single-shielded data sheet publishes construction, jacket O.D. and temperature range, not a characteristic-impedance value. If the project documentation has to carry one, say so in the enquiry.
  • Length, packing and termination — 100 m rolls, 305 m drums or custom lengths, with XLR male/female pre-assembly available on request.

제품 소싱 FAQ

견적을 요청하기 전에

이러한 답변은 이 페이지에 표시된 제품 정보를 사용합니다. 최종 프로젝트 기간은 확정된 사양에 따라 달라집니다.

LBSDMX128035-1을 인용하려면 어떤 정보가 필요합니까?

필요한 사양, 길이 또는 포장 단위, 수량, 용도 및 도착 국가 또는 지역을 알려주십시오.

OEM/ODM 프로젝트에서 단일 차폐 DMX512 조명 제어 케이블을 논의할 수 있나요?

확정된 제품 및 프로젝트 수량에 따라 구성, 재킷 색상, 프린팅, 길이, 포장, 브랜딩 등을 검토할 수 있습니다.

올바른 변형을 어떻게 선택합니까?

이 페이지의 기술 사양 표를 비교한 후 변형 확인에 도움이 필요한 경우 LBS에 애플리케이션과 필수 치수를 보내주세요.

견적을 요청하세요

이 제품에 대해 물어보세요

아래의 주요 세부정보를 작성하세요. 메시지는 LBS 영업팀으로 직접 전송되며 의도적으로 WordPress의 리드 레코드로 저장되지 않습니다.

OEM/ODM문의

귀하의 프로젝트에 필요한 것이 무엇인지 알려주십시오.

모델, 사양, 수량, 목적지를 보내세요. 저희 팀에서 다음 단계로 답변해 드리겠습니다.

WhatsApp 견적 받기