Passer au contenu
Fabrication professionnelle de câbles audio, d'éclairage et AV
LBS LBS AudioCable Factory乐宝声(广东)线缆科技有限公司
🇫🇷 Français
LBSFTP-C6A

Câble à paire torsadée blindé FTP Cat6A

Câble Cat6A blindé par feuille avec un fil de drainage en cuivre étamé, des conducteurs OFC solides de 23 AWG et une bande passante de 250 MHz.

Vitesse/bande passante1000 Mbps / 250 MHz
Couleur de la vesteBlue
Veste O.D.7.2 mm
VestePVC
Conducteur principal23 AWG / 0.25
BouclierAL-Foil + Tinned-Copper Drain Wire
Température-20°C to 70°C

Cat6A FTP Shielded Twisted Pair Cable. AL-foil shield, tinned-copper drain wire, blue PVC jacket, O.D. 7.2mm, 23AWG solid 4N OFC, cross-filler spline, -20 to +70C. 1Gbps/250MHz. From LBS Catalog 2026.

Cat6A FTP for Shielded 10Gbps Runs

This Cat6A FTP cable adds an aluminium-foil shield and tinned-copper drain wire over the 23AWG solid 4N OFC Cat6A core. The foil shield provides protection against external interference while the drain wire gives a clean termination point for the shield. Cat6A FTP is a practical middle option for 10Gbps horizontal runs where the cable passes near power feeders or lighting circuits but a full double-shielded SFTP cable is not required.

Compare the shielding levels in the LBS Cat6A family: Cat6A UTP (unshielded), this FTP (foil), and Cat6A SFTP (foil plus braid). See UTP vs FTP vs SFTP Ethernet Cable for the full comparison, and the LBS6ASSTP-C6A Cat6A S/FTP 10G cable for the double-shielded backbone option.

Applications / 应用

10Gbps data backbones, AV-over-IP (Dante, AVB, NDI), building network risers, PoE+ cameras and general commercial network installation where foil shielding is specified.

Cat6A FTP FAQ

Q: What is the difference between Cat6A FTP and Cat6A SFTP?
A: FTP uses one aluminium-foil shield over the core. SFTP uses foil plus an overall tinned-copper braid for double shielding, giving more noise immunity in electrically noisy environments.

Q: Does Cat6A FTP support 10Gbps?
A: The LBS 2026 catalog lists this foil-shielded Cat6A construction as Gigabit Ethernet (1000 Mbps / 1 Gbps) with transmission bandwidth up to 250 MHz. The shield type affects noise immunity, not the Gigabit rating. Where a 10 Gbps / 500 MHz backbone is specified, LBS supplies the Cat6A S/FTP 10G construction (LBS6ASSTP-C6A).

Q: Can the drain wire be terminated in standard RJ45?
A: The drain wire is intended to be connected to the shield at the patch panel or equipment end. Your installer should follow the connector manufacturer’s shielded termination instructions.

Cat6A Family Comparison: UTP / FTP / SFTP / S-FTP 10G

Every Cat6A construction in the LBS range shares the same 23 AWG solid 4N OFC conductor and an internal cross-filler spline that keeps the four pairs separated. The buyer choice is the shielding level — and, for the 10G backbone item, the insulation and bandwidth rating. The table uses the values published in the LBS 2026 product catalog, Cat6A series:

Item / construction Shielding Jacket O.D. Main conductor Catalogued speed / bandwidth
Cat6A UTP (LBSUTP-C6A)
Unshielded twisted pair
None 6.2 / 6.4 / 7.2 mm 23 AWG / 0.25 Gigabit Ethernet (1000 Mbps / 1 Gbps), up to 250 MHz
Cat6A FTP (LBSFTP-C6A) (this page)
Foil shield + tinned-copper drain wire
AL-foil + drain wire 7.2 mm 23 AWG / 0.25 Gigabit Ethernet (1000 Mbps / 1 Gbps), up to 250 MHz
Cat6A SFTP (LBSSFTP-C6A)
AL-foil plus overall tinned-copper braid
Foil + braid (double) 7.8 mm 23 AWG / 0.26 Gigabit Ethernet (1000 Mbps / 1 Gbps), up to 250 MHz
Cat6A S/FTP 10G (LBS6ASSTP-C6A)
Individually foil-shielded pairs + overall tinned-copper braid, Foam-PE insulation
Foil per pair + braid 8 mm 23 AWG / 0.26 10 Gigabit (10 Gbps), up to 500 MHz

All four constructions: blue PVC jacket, applicable temperature -20°C to +70°C. Source: LBS 2026 product catalog, Cat6A series. Confirm the exact SKU and construction for your project before ordering.

Selection rule: pick the lowest shielding level the installation actually needs — UTP for clean dedicated data/AV runs, FTP where the run passes near power feeders or lighting circuits, SFTP on stage floors, touring racks and high-EMI routes, and the Cat6A S/FTP 10G item where a 10 Gbps / 500 MHz backbone is specified. For the shielding comparison in detail, see the UTP vs FTP vs SFTP Ethernet Cable guide.

Cat6A 系列对比:四种结构同为 23 AWG 实心 4N 无氧铜导体并带十字骨架,区别在屏蔽等级;表中数值取自 LBS 2026 产品目录 Cat6A 系列页。

📥 Download Full Product Catalog (PDF)

AV over IP Network Cable Selection

In an AV-over-IP project — Dante audio, NDI video, SDVoE or control networks — the Cat6A FTP construction is often the practical choice for links that run through equipment racks, cable trays and corridors where some electrical noise exists but a full double-shielded cable is not required. Three selection rules apply:

  • Shielding level follows the environment. Clean dedicated AV network runs can use Cat6A UTP; runs near dimmers, lighting racks or power feeders should use at least FTP; stage floors, touring racks and high-EMI locations should use Cat6A SFTP.
  • Category follows the protocol. Gigabit audio control systems run comfortably on Cat6A at 250 MHz; video-heavy systems (4K over NDI or SDVoE) benefit from the 10 Gbps / 500 MHz Cat6A S/FTP backbone.
  • Keep one construction per link. Mixing UTP and FTP sections on the same run creates grounding and performance questions — standardise the family on one shielding level per zone.

The LBS Cat6A family covers all three shielding levels with the same 23 AWG solid OFC core and cross-filler spline: Cat6A UTP, this Cat6A FTP, Cat6A SFTP and the Cat6A S/FTP 10G. For a full AV-over-IP specification walkthrough, see the AV over IP network cable guide.

Related Guides

FAQ SUR L'APPROVISIONNEMENT DE PRODUITS

Avant de demander un devis

Ces réponses utilisent les informations sur le produit affichées sur cette page. Les conditions finales du projet dépendent de la spécification confirmée.

Quelles informations sont nécessaires pour citer LBSFTP-C6A

Veuillez fournir les spécifications requises, la longueur ou l'unité d'emballage, la quantité, l'application et le pays ou la région de destination.

Le Câble à paire torsadée blindé FTP Cat6A peut-il être discuté pour un projet OEM/ODM

La construction, la couleur de la veste, l'impression, la longueur, l'emballage et la marque peuvent être examinés en fonction du produit confirmé et de la quantité du projet.

Comment choisir la bonne variante ?

Comparez le tableau des spécifications techniques sur cette page, puis envoyez à LBS la demande et les dimensions requises si vous avez besoin d'aide pour confirmer une variante.

DEMANDER UN DEVIS

Renseignez-vous sur ce produit

Complétez les détails clés ci-dessous. Le message est envoyé directement aux ventes LBS et n'est pas intentionnellement stocké en tant qu'enregistrement de prospect dans WordPress.

Utilisez plutôt WhatsApp

Demande d'OEM/ODM

Dites-nous quels sont les besoins de votre projet.

Envoyez le modèle, les spécifications, la quantité et la destination. Notre équipe vous répondra à l'étape suivante.

WhatsApp Obtenir un devis