كابل زوج ملتوي محمي من Cat6A FTP. درع من رقائق الألومنيوم، وسلك تصريف من النحاس المعلب، وسترة PVC زرقاء، وOD. 7.2 مم، 23AWG صلب 4N OFC، شريحة حشو متقاطعة، -20 إلى 70 درجة مئوية. 1 جيجابت في الثانية/250 ميجاهرتز. من كتالوج LBS 2026.
Cat6A FTP for Shielded 10Gbps Runs
This Cat6A FTP cable adds an aluminium-foil shield and tinned-copper drain wire over the 23AWG solid 4N OFC Cat6A core. The foil shield provides protection against external interference while the drain wire gives a clean termination point for the shield. Cat6A FTP is a practical middle option for 10Gbps horizontal runs where the cable passes near power feeders or lighting circuits but a full double-shielded SFTP cable is not required.
Compare the shielding levels in the LBS Cat6A family:Cat6A UTP(unshielded), this FTP (foil), andCat6A SFTP(foil plus braid). SeeUTP مقابل FTP مقابل كابل إيثرنت SFTPfor the full comparison, and theLBS6ASSTP-C6A Cat6A S/FTP 10G cablefor the double-shielded backbone option.
التطبيقات / 应用
10Gbps data backbones, AV-over-IP (Dante, AVB, NDI), building network risers, PoE+ cameras and general commercial network installation where foil shielding is specified.
Cat6A FTP FAQ
Q: What is the difference between Cat6A FTP and Cat6A SFTP?
A: FTP uses one aluminium-foil shield over the core. SFTP uses foil plus an overall tinned-copper braid for double shielding, giving more noise immunity in electrically noisy environments.
Q: Does Cat6A FTP support 10Gbps?
A: Yes. Cat6A is specified for 10GBASE-T up to 100 metres; the shield type affects noise immunity, not the 10G capability.
Q: Can the drain wire be terminated in standard RJ45?
A: The drain wire is intended to be connected to the shield at the patch panel or equipment end. Your installer should follow the connector manufacturer’s shielded termination instructions.
📥 تنزيل كتالوج المنتجات الكامل (PDF)
AV over IP Network Cable Selection
In an AV-over-IP project — Dante audio, NDI video, SDVoE or control networks — the Cat6A FTP construction is often the practical choice for links that run through equipment racks, cable trays and corridors where some electrical noise exists but a full double-shielded cable is not required. Three selection rules apply:
- Shielding level follows the environment.Clean dedicated AV network runs can use Cat6A UTP; runs near dimmers, lighting racks or power feeders should use at least FTP; stage floors, touring racks and high-EMI locations should use Cat6A SFTP.
- Category follows the protocol.Gigabit audio control systems run comfortably on Cat6A at 250 MHz; video-heavy systems (4K over NDI or SDVoE) benefit from the 10 Gbps / 500 MHz Cat6A S/FTP backbone.
- Keep one construction per link.Mixing UTP and FTP sections on the same run creates grounding and performance questions — standardise the family on one shielding level per zone.
The LBS Cat6A family covers all three shielding levels with the same 23 AWG solid OFC core and cross-filler spline:Cat6A UTP, thisCat6A FTP,Cat6A SFTPوCat6A S/FTP 10G. For a full AV-over-IP specification walkthrough, see theAV over IP network cable guide.