コンテンツにスキップ
プロのオーディオ、照明、AV ケーブルの製造
LBS LBS AudioCable Factory乐宝声(广东)线缆科技有限公司
🇯🇵 日本語
LBSDMX96050-1

シングルシールド DMX512 照明制御ケーブル

舞台照明用の片シールド 2 芯シールド DMX512 照明制御ケーブル、96 / 2 × 0.50 編組、6.3 mm マット EPVC ジャケット、高密度 OFC スパイラル シールド (カバー率 85%)。

商品番号LBSDMX96050
導体2
ジャケットの色Black / brown / dark green optional
ジャケット外径6.3 mm
ジャケットEPVC MATT
シールドSingle shield — high-density OFC spiral, 85%+ coverage
編み込み96 / 2 × 0.50
適用温度-20°C to 70°C

Features

Elastic PVC jacket, PE insulation, high-density OFC spiral shielding (85%+ coverage) for reliable DMX512 signal transmission.

Applications / 应用

DMX512 lighting control, stage equipment, KTV and professional show installations.

DMX512灯光控制、舞台设备、KTV与专业演出应用。

DMX512 impedance: what the standard says, and what this data sheet states

DMX512 runs on the RS-485 electrical layer. RS-485 is specified around a 120 Ω nominal characteristic impedance on shielded twisted-pair cable, and impedance comes from the construction — conductor spacing, insulation and shield geometry — not from the copper size alone.

LBS publishes 120 Ω on the double-shielded LBSDMX…-2 models. On this single-shielded model the published data sheet states shield type, braiding, jacket O.D. and temperature range, and does not state an impedance figure. If your project documentation has to carry one, request the value against this model instead of assuming it.

Why the figure matters: DMX termination and daisy-chain rules →

DMX512 single shielded stage lighting control cable construction diagram

Single-shield or double-shield: what the order has to state

LBS builds two DMX512 families with the same two conductors, the same 6.3 mm matt EPVC jacket and the same -20 °C to +70 °C rating. The difference is the shield, and that is the line the purchase order has to be specific about.

Construction Shield Impedance on the published data sheet Model example
Single-shielded (this page) High-density OFC spiral, 85%+ coverage Not stated LBSDMX96050
Double-shielded 100% coverage AL-Foil plus heavy-duty tinned-copper braid 120 Ω LBSDMX96050-2

Where the run shares a tray, a truss or a cable path with dimmer racks, LED power supplies or motor drives, the foil layer under the braid is the reason to specify the double-shielded construction. Where the data pair is routed clear of that equipment, the single-shielded spiral is the simpler build and the usual choice.

See the double-shielded LBSDMX96050-2 construction →  ·  All DMX lighting cable

OEM and Customisation for DMX512 Lighting Control Cable

The LBSDMX series can be produced to your specification for branded or project requirements:

  • Conductor and construction: 2-core single-shielded DMX512 lighting control cable, braiding 96 / 2 × 0.50, high-density OFC spiral shield at 85%+ coverage
  • Jacket: matt EPVC in black, brown or dark green, custom colours on request
  • Printing: your brand name, model number and specification printed on the jacket
  • Packaging: 100 m rolls, 305 m drums or custom lengths for distributor stocking
  • Pre-assembly: XLR male/female termination available on request

Request an OEM quotation for DMX512 lighting control cable →

FAQ

What is the difference between LBSDMX96050 and LBSDMX96050-2?

LBSDMX96050 is single-shielded: a high-density OFC spiral at 85%+ coverage. LBSDMX96050-2 is the double-shielded construction, 100% coverage AL-Foil plus a heavy-duty tinned-copper braid, and it publishes a 120 Ω characteristic impedance. Conductor count, jacket and temperature rating are the same on both.

What characteristic impedance does this cable have?

The published data sheet for the single-shielded family states the shield type, braiding, jacket O.D. and temperature range, and does not state an impedance figure. The double-shielded family states 120 Ω. If your tender or project documentation has to carry an impedance value, ask for it against the specific model rather than assuming one.

Can it be terminated with 5-pin XLR?

Yes — LBS supplies pre-assembled XLR-terminated DMX512 lighting control cable on request. Send the connector gender, pin count, length and quantity with the enquiry.

Is this the same as a microphone cable?

No. Both are shielded twisted constructions, but DMX512 runs on the RS-485 electrical layer, which specifies a 120 Ω nominal characteristic impedance, while microphone cable is built for balanced audio. See DMX cable vs microphone cable.

LBSDMX Single-Shielded Series — Variants

The single-shielded family is built in seven braiding sizes on the same 6.3 mm jacket. Match the braiding to the mechanical duty of the run; the conductor count does not change.

Model Braiding (cores × conductor) Shield Product page
LBSDMX64025 64 / 2 × 0.25 Single shield — high-density OFC spiral, 85%+ coverage View
LBSDMX96035 96 / 2 × 0.35 Single shield — high-density OFC spiral, 85%+ coverage View
LBSDMX96050 96 / 2 × 0.50 Single shield — high-density OFC spiral, 85%+ coverage Current page
LBSDMX128035 128 / 2 × 0.35 Single shield — high-density OFC spiral, 85%+ coverage View
LBSDMX128050 128 / 2 × 0.50 Single shield — high-density OFC spiral, 85%+ coverage View
LBSDMX144050 144 / 2 × 0.50 Single shield — high-density OFC spiral, 85%+ coverage View
LBSDMX168050 168 / 2 × 0.50 Single shield — high-density OFC spiral, 85%+ coverage View

Related Guides

製品調達に関するよくある質問

お見積りを依頼する前に

これらの回答には、このページに表示されている製品情報が使用されています。最終的なプロジェクト条件は確認された仕様によって異なります。

LBSDMX96050-1 を見積もるにはどのような情報が必要ですか

ご希望の仕様、長さまたは梱包単位、数量、用途、送り先の国または地域をお知らせください。

シングルシールド DMX512 照明制御ケーブルを OEM / ODM プロジェクトで議論できますか?

確認された製品とプロジェクトの数量に応じて、構造、ジャケットの色、印刷、長さ、パッケージング、およびブランディングを検討できます。

正しいバリアントを選択するにはどうすればよいですか?

このページの技術仕様表を比較し、バリアントの確認にサポートが必要な場合は、アプリケーションと必要な寸法を LBS に送信してください。

見積もりを依頼する

この商品について質問する

以下の主要な詳細を入力してください。メッセージは LBS 営業に直接送信され、WordPress に潜在顧客レコードとして意図的に保存されることはありません。

代わりに WhatsApp を使用してください

OEM/ODMのお問い合わせ

あなたのプロジェクトに何が必要かを教えてください。

型式、仕様、数量、送付先をお送りください。私たちのチームが次のステップについて返信します。

WhatsApp 見積もりを取得する