Passer au contenu
Fabrication professionnelle de câbles audio, d'éclairage et AV
LBS LBS AudioCable Factory乐宝声(广东)线缆科技有限公司
🇫🇷 Français
LBSDMX168050-1

Câble de commande d'éclairage DMX512 à blindage unique

Câble de commande d'éclairage DMX512 monofilaire à 2 conducteurs blindés pour éclairage de scène, tresse 168 / 2 × 0,50, gaine EPVC mate 6,3 mm, blindage spiralé OFC haute densité (couverture 85%).

Numéro d'article.LBSDMX168050
Conducteurs2
Couleur de la vesteBlack / brown / dark green optional
Veste O.D.6.3 mm
VesteEPVC MATT
BlindageSingle shield — high-density OFC spiral, 85%+ coverage
Tressage168 / 2 × 0.50
Température applicable-20°C to 70°C

Features

Elastic PVC jacket, PE insulation, high-density OFC spiral shielding (85%+ coverage) for reliable DMX512 signal transmission.

Applications / 应用

DMX512 lighting control, stage equipment, KTV and professional show installations.

DMX512灯光控制、舞台设备、KTV与专业演出应用。

DMX512 impedance: what the standard says, and what this data sheet states

DMX512 runs on the RS-485 electrical layer. RS-485 is specified around a 120 Ω nominal characteristic impedance on shielded twisted-pair cable, and impedance comes from the construction — conductor spacing, insulation and shield geometry — not from the copper size alone.

LBS publishes 120 Ω on the double-shielded LBSDMX…-2 models. On this single-shielded model the published data sheet states shield type, braiding, jacket O.D. and temperature range, and does not state an impedance figure. If your project documentation has to carry one, request the value against this model instead of assuming it.

Why the figure matters: DMX termination and daisy-chain rules →

DMX512 single shielded stage lighting control cable construction diagram

Single-shield or double-shield: what the order has to state

LBS builds two DMX512 families with the same two conductors, the same 6.3 mm matt EPVC jacket and the same -20 °C to +70 °C rating. The difference is the shield, and that is the line the purchase order has to be specific about.

Construction Shield Impedance on the published data sheet Model example
Single-shielded (this page) High-density OFC spiral, 85%+ coverage Not stated LBSDMX168050
Double-shielded 100% coverage AL-Foil plus heavy-duty tinned-copper braid 120 Ω LBSDMX168050-2

Where the run shares a tray, a truss or a cable path with dimmer racks, LED power supplies or motor drives, the foil layer under the braid is the reason to specify the double-shielded construction. Where the data pair is routed clear of that equipment, the single-shielded spiral is the simpler build and the usual choice.

See the double-shielded LBSDMX168050-2 construction →  ·  All DMX lighting cable

OEM and Customisation for DMX512 Lighting Control Cable

The LBSDMX series can be produced to your specification for branded or project requirements:

  • Conductor and construction: 2-core single-shielded DMX512 lighting control cable, braiding 168 / 2 × 0.50, high-density OFC spiral shield at 85%+ coverage
  • Jacket: matt EPVC in black, brown or dark green, custom colours on request
  • Printing: your brand name, model number and specification printed on the jacket
  • Packaging: 100 m rolls, 305 m drums or custom lengths for distributor stocking
  • Pre-assembly: XLR male/female termination available on request

Request an OEM quotation for DMX512 lighting control cable →

FAQ

What is the difference between LBSDMX168050 and LBSDMX168050-2?

LBSDMX168050 is single-shielded: a high-density OFC spiral at 85%+ coverage. LBSDMX168050-2 is the double-shielded construction, 100% coverage AL-Foil plus a heavy-duty tinned-copper braid, and it publishes a 120 Ω characteristic impedance. Conductor count, jacket and temperature rating are the same on both.

What characteristic impedance does this cable have?

The published data sheet for the single-shielded family states the shield type, braiding, jacket O.D. and temperature range, and does not state an impedance figure. The double-shielded family states 120 Ω. If your tender or project documentation has to carry an impedance value, ask for it against the specific model rather than assuming one.

Can it be terminated with 5-pin XLR?

Yes — LBS supplies pre-assembled XLR-terminated DMX512 lighting control cable on request. Send the connector gender, pin count, length and quantity with the enquiry.

Is this the same as a microphone cable?

No. Both are shielded twisted constructions, but DMX512 runs on the RS-485 electrical layer, which specifies a 120 Ω nominal characteristic impedance, while microphone cable is built for balanced audio. See DMX cable vs microphone cable.

LBSDMX Single-Shielded Series — Variants

The single-shielded family is built in seven braiding sizes on the same 6.3 mm jacket. Match the braiding to the mechanical duty of the run; the conductor count does not change.

Model Braiding (cores × conductor) Shield Product page
LBSDMX64025 64 / 2 × 0.25 Single shield — high-density OFC spiral, 85%+ coverage View
LBSDMX96035 96 / 2 × 0.35 Single shield — high-density OFC spiral, 85%+ coverage View
LBSDMX96050 96 / 2 × 0.50 Single shield — high-density OFC spiral, 85%+ coverage View
LBSDMX128035 128 / 2 × 0.35 Single shield — high-density OFC spiral, 85%+ coverage View
LBSDMX128050 128 / 2 × 0.50 Single shield — high-density OFC spiral, 85%+ coverage View
LBSDMX144050 144 / 2 × 0.50 Single shield — high-density OFC spiral, 85%+ coverage View
LBSDMX168050 168 / 2 × 0.50 Single shield — high-density OFC spiral, 85%+ coverage Current page

Related Guides

FAQ SUR L'APPROVISIONNEMENT DE PRODUITS

Avant de demander un devis

Ces réponses utilisent les informations sur le produit affichées sur cette page. Les conditions finales du projet dépendent de la spécification confirmée.

Quelles informations sont nécessaires pour citer LBSDMX168050-1

Veuillez fournir les spécifications requises, la longueur ou l'unité d'emballage, la quantité, l'application et le pays ou la région de destination.

Le Câble de commande d'éclairage DMX512 à blindage unique peut-il être discuté pour un projet OEM / ODM

La construction, la couleur de la veste, l'impression, la longueur, l'emballage et la marque peuvent être examinés en fonction du produit confirmé et de la quantité du projet.

Comment choisir la bonne variante ?

Comparez le tableau des spécifications techniques sur cette page, puis envoyez à LBS la demande et les dimensions requises si vous avez besoin d'aide pour confirmer une variante.

DEMANDER UN DEVIS

Renseignez-vous sur ce produit

Complétez les détails clés ci-dessous. Le message est envoyé directement aux ventes LBS et n'est pas intentionnellement stocké en tant qu'enregistrement de prospect dans WordPress.

Utilisez plutôt WhatsApp

Demande d'OEM/ODM

Dites-nous quels sont les besoins de votre projet.

Envoyez le modèle, les spécifications, la quantité et la destination. Notre équipe vous répondra à l'étape suivante.

WhatsApp Obtenir un devis