跳至內容
專業音響、燈光、AV線製造
LBS LBS AudioCable Factory乐宝声(广东)线缆科技有限公司
🇭🇰 繁體中文
LBSDMX96035-1

单屏蔽 DMX512 灯光控制线 - 96/2×0.35

单屏蔽两芯带屏蔽 DMX512 灯光控制线,适用于舞台灯光信号传输,编织 96 / 2 × 0.35,6.3mm 哑光 EPVC 护套,高密度无氧铜螺旋屏蔽(覆盖率 85% 以上)。

型号LBSDMX96035
导体数2
外层颜色Black / brown / dark green optional
标称外径6.3 mm
外层护套EPVC MATT
屏蔽结构Single shield — high-density OFC spiral, 85%+ coverage
编织网数96 / 2 × 0.35
适用温度-20°C to 70°C

Features

Elastic PVC jacket, PE insulation, high-density OFC spiral shielding (85%+ coverage) for reliable DMX512 signal transmission.

Applications / 应用

DMX512 lighting control, stage equipment, KTV and professional show installations.

DMX512灯光控制、舞台设备、KTV与专业演出应用。

DMX512 impedance: what the standard says, and what this data sheet states

DMX512 runs on the RS-485 electrical layer. RS-485 is specified around a 120 Ω nominal characteristic impedance on shielded twisted-pair cable, and impedance comes from the construction — conductor spacing, insulation and shield geometry — not from the copper size alone.

LBS publishes 120 Ω on the double-shielded LBSDMX…-2 models. On this single-shielded model the published data sheet states shield type, braiding, jacket O.D. and temperature range, and does not state an impedance figure. If your project documentation has to carry one, request the value against this model instead of assuming it.

Why the figure matters: DMX termination and daisy-chain rules →

DMX512 single shielded stage lighting control cable construction diagram

Single-shield or double-shield: what the order has to state

LBS builds two DMX512 families with the same two conductors, the same 6.3 mm matt EPVC jacket and the same -20 °C to +70 °C rating. The difference is the shield, and that is the line the purchase order has to be specific about.

Construction Shield Impedance on the published data sheet Model example
Single-shielded (this page) High-density OFC spiral, 85%+ coverage Not stated LBSDMX96035
Double-shielded 100% coverage AL-Foil plus heavy-duty tinned-copper braid 120 Ω LBSDMX96035-2

Where the run shares a tray, a truss or a cable path with dimmer racks, LED power supplies or motor drives, the foil layer under the braid is the reason to specify the double-shielded construction. Where the data pair is routed clear of that equipment, the single-shielded spiral is the simpler build and the usual choice.

See the double-shielded LBSDMX96035-2 construction →  ·  All DMX lighting cable

OEM and Customisation for DMX512 Lighting Control Cable

The LBSDMX series can be produced to your specification for branded or project requirements:

  • Conductor and construction: 2-core single-shielded DMX512 lighting control cable, braiding 96 / 2 × 0.35, high-density OFC spiral shield at 85%+ coverage
  • Jacket: matt EPVC in black, brown or dark green, custom colours on request
  • Printing: your brand name, model number and specification printed on the jacket
  • Packaging: 100 m rolls, 305 m drums or custom lengths for distributor stocking
  • Pre-assembly: XLR male/female termination available on request

Request an OEM quotation for DMX512 lighting control cable →

FAQ

What is the difference between LBSDMX96035 and LBSDMX96035-2?

LBSDMX96035 is single-shielded: a high-density OFC spiral at 85%+ coverage. LBSDMX96035-2 is the double-shielded construction, 100% coverage AL-Foil plus a heavy-duty tinned-copper braid, and it publishes a 120 Ω characteristic impedance. Conductor count, jacket and temperature rating are the same on both.

What characteristic impedance does this cable have?

The published data sheet for the single-shielded family states the shield type, braiding, jacket O.D. and temperature range, and does not state an impedance figure. The double-shielded family states 120 Ω. If your tender or project documentation has to carry an impedance value, ask for it against the specific model rather than assuming one.

Can it be terminated with 5-pin XLR?

Yes — LBS supplies pre-assembled XLR-terminated DMX512 lighting control cable on request. Send the connector gender, pin count, length and quantity with the enquiry.

Is this the same as a microphone cable?

No. Both are shielded twisted constructions, but DMX512 runs on the RS-485 electrical layer, which specifies a 120 Ω nominal characteristic impedance, while microphone cable is built for balanced audio. See DMX cable vs microphone cable.

LBSDMX Single-Shielded Series — Variants

The single-shielded family is built in seven braiding sizes on the same 6.3 mm jacket. Match the braiding to the mechanical duty of the run; the conductor count does not change.

Model Braiding (cores × conductor) Shield Product page
LBSDMX64025 64 / 2 × 0.25 Single shield — high-density OFC spiral, 85%+ coverage View
LBSDMX96035 96 / 2 × 0.35 Single shield — high-density OFC spiral, 85%+ coverage Current page
LBSDMX96050 96 / 2 × 0.50 Single shield — high-density OFC spiral, 85%+ coverage View
LBSDMX128035 128 / 2 × 0.35 Single shield — high-density OFC spiral, 85%+ coverage View
LBSDMX128050 128 / 2 × 0.50 Single shield — high-density OFC spiral, 85%+ coverage View
LBSDMX144050 144 / 2 × 0.50 Single shield — high-density OFC spiral, 85%+ coverage View
LBSDMX168050 168 / 2 × 0.50 Single shield — high-density OFC spiral, 85%+ coverage View

Related Guides

產品採購常見問題解答

在請求報價之前

這些答案使用此頁面上顯示的產品資訊。最終項目條款取決於已確認的規格。

询价 LBSDMX96035-1 需要提供什么信息?

請提供所需規格、長度或包裝單位、數量、用途及目的國家或地區。

单屏蔽 DMX512 灯光控制线 - 96/2×0.35 是否可以沟通 OEM / ODM 项目?

結構、外套顏色、印刷、長度、包裝和品牌可以根據確認的產品和項目數量進行審核。

我如何選擇正確的變體?

如果您需要協助確認型號,請比較本頁上的技術​​規格表,然後向 LBS 發送應用程式和所需尺寸。

索取報價

詢問該產品

完成下面的關鍵詳細資訊。該訊息會直接傳送給 LBS 銷售人員,並且不會刻意將其儲存為 WordPress 中的潛在客戶記錄。

OEM/ODM詢價

告訴我們您的專案需要什麼。

發送型號、規格、數量和目的地。我們的團隊將回覆下一步。

WhatsApp 取得報價