LBSDMX144050-1

단일 차폐 DMX512 조명 제어 케이블

무대 조명용 단일 차폐 2코어 차폐 DMX512 조명 제어 케이블, 편조 144/2 × 0.50, 6.3mm 무광택 EPVC 재킷, 고밀도 OFC 나선형 차폐(85% 적용 범위).

품목 번호LBSDMX144050
지휘자2
재킷 색상Black / brown / dark green optional
재킷 O.D.6.3 mm
재킷EPVC MATT
차폐Single shield — high-density OFC spiral, 85%+ coverage
땋기144 / 2 × 0.50
적용온도-20°C to 70°C

Features

Elastic PVC jacket, PE insulation, high-density OFC spiral shielding (85%+ coverage) for reliable DMX512 signal transmission.

Applications / 应用

DMX512 lighting control, stage equipment, KTV and professional show installations.

DMX512灯光控制、舞台设备、KTV与专业演出应用。

DMX512 impedance: what the standard says, and what this data sheet states

DMX512 runs on the RS-485 electrical layer. RS-485 is specified around a 120 Ω nominal characteristic impedance on shielded twisted-pair cable, and impedance comes from the construction — conductor spacing, insulation and shield geometry — not from the copper size alone.

LBS publishes 120 Ω on the double-shielded LBSDMX…-2 models. On this single-shielded model the published data sheet states shield type, braiding, jacket O.D. and temperature range, and does not state an impedance figure. If your project documentation has to carry one, request the value against this model instead of assuming it.

Why the figure matters: DMX termination and daisy-chain rules →

DMX512 single shielded stage lighting control cable construction diagram

Single-shield or double-shield: what the order has to state

LBS builds two DMX512 families with the same two conductors, the same 6.3 mm matt EPVC jacket and the same -20 °C to +70 °C rating. The difference is the shield, and that is the line the purchase order has to be specific about.

Construction Shield Impedance on the published data sheet Model example
Single-shielded (this page) High-density OFC spiral, 85%+ coverage Not stated LBSDMX144050
Double-shielded 100% coverage AL-Foil plus heavy-duty tinned-copper braid 120 Ω LBSDMX144050-2

Where the run shares a tray, a truss or a cable path with dimmer racks, LED power supplies or motor drives, the foil layer under the braid is the reason to specify the double-shielded construction. Where the data pair is routed clear of that equipment, the single-shielded spiral is the simpler build and the usual choice.

See the double-shielded LBSDMX144050-2 construction →  ·  All DMX lighting cable

OEM and Customisation for DMX512 Lighting Control Cable

The LBSDMX series can be produced to your specification for branded or project requirements:

  • Conductor and construction: 2-core single-shielded DMX512 lighting control cable, braiding 144 / 2 × 0.50, high-density OFC spiral shield at 85%+ coverage
  • Jacket: matt EPVC in black, brown or dark green, custom colours on request
  • Printing: your brand name, model number and specification printed on the jacket
  • Packaging: 100 m rolls, 305 m drums or custom lengths for distributor stocking
  • Pre-assembly: XLR male/female termination available on request

Request an OEM quotation for DMX512 lighting control cable →

FAQ

What is the difference between LBSDMX144050 and LBSDMX144050-2?

LBSDMX144050 is single-shielded: a high-density OFC spiral at 85%+ coverage. LBSDMX144050-2 is the double-shielded construction, 100% coverage AL-Foil plus a heavy-duty tinned-copper braid, and it publishes a 120 Ω characteristic impedance. Conductor count, jacket and temperature rating are the same on both.

What characteristic impedance does this cable have?

The published data sheet for the single-shielded family states the shield type, braiding, jacket O.D. and temperature range, and does not state an impedance figure. The double-shielded family states 120 Ω. If your tender or project documentation has to carry an impedance value, ask for it against the specific model rather than assuming one.

Can it be terminated with 5-pin XLR?

Yes — LBS supplies pre-assembled XLR-terminated DMX512 lighting control cable on request. Send the connector gender, pin count, length and quantity with the enquiry.

Is this the same as a microphone cable?

No. Both are shielded twisted constructions, but DMX512 runs on the RS-485 electrical layer, which specifies a 120 Ω nominal characteristic impedance, while microphone cable is built for balanced audio. See DMX cable vs microphone cable.

LBSDMX Single-Shielded Series — Variants

The single-shielded family is built in seven braiding sizes on the same 6.3 mm jacket. Match the braiding to the mechanical duty of the run; the conductor count does not change.

Model Braiding (cores × conductor) Shield Product page
LBSDMX64025 64 / 2 × 0.25 Single shield — high-density OFC spiral, 85%+ coverage View
LBSDMX96035 96 / 2 × 0.35 Single shield — high-density OFC spiral, 85%+ coverage View
LBSDMX96050 96 / 2 × 0.50 Single shield — high-density OFC spiral, 85%+ coverage View
LBSDMX128035 128 / 2 × 0.35 Single shield — high-density OFC spiral, 85%+ coverage View
LBSDMX128050 128 / 2 × 0.50 Single shield — high-density OFC spiral, 85%+ coverage View
LBSDMX144050 144 / 2 × 0.50 Single shield — high-density OFC spiral, 85%+ coverage Current page
LBSDMX168050 168 / 2 × 0.50 Single shield — high-density OFC spiral, 85%+ coverage View

Related Guides

제품 소싱 FAQ

견적을 요청하기 전에

이러한 답변은 이 페이지에 표시된 제품 정보를 사용합니다. 최종 프로젝트 기간은 확정된 사양에 따라 달라집니다.

LBSDMX144050-1을 인용하려면 어떤 정보가 필요합니까?

필요한 사양, 길이 또는 포장 단위, 수량, 용도 및 도착 국가 또는 지역을 알려주십시오.

OEM/ODM 프로젝트에서 단일 차폐 DMX512 조명 제어 케이블을 논의할 수 있나요?

확정된 제품 및 프로젝트 수량에 따라 구성, 재킷 색상, 프린팅, 길이, 포장, 브랜딩 등을 검토할 수 있습니다.

올바른 변형을 어떻게 선택합니까?

이 페이지의 기술 사양 표를 비교한 후 변형 확인에 도움이 필요한 경우 LBS에 애플리케이션과 필수 치수를 보내주세요.

견적을 요청하세요

이 제품에 대해 물어보세요

아래의 주요 세부정보를 작성하세요. 메시지는 LBS 영업팀으로 직접 전송되며 의도적으로 WordPress의 리드 레코드로 저장되지 않습니다.

OEM/ODM문의

귀하의 프로젝트에 필요한 것이 무엇인지 알려주십시오.

모델, 사양, 수량, 목적지를 보내세요. 저희 팀에서 다음 단계로 답변해 드리겠습니다.

WhatsApp 견적 받기